Similar to lubricant analysis, the main goal in coolant analysis is preventive maintenance. This process involves monitoring the health of the coolant as well as the health of the overall cooling system before catastrophic failures occur.
Analyzing Conventional Coolants (CC) and Extended Life Coolants (ELC) for acceptable continued use has proven to optimize reliability, decrease unscheduled downtime, and reduce component failures.
TESTS |
CC-1 |
CC-2 |
ELC-1 |
ELC-2 |
---|---|---|---|---|
Freeze Point | ✔ |
✔ |
✔ |
✔ |
PH | ✔ |
✔ |
✔ |
✔ |
Total Dissolved Solids | ✔ |
|||
Glycol % / Antifreeze % | ✔ |
✔ |
✔ |
✔ |
Elemental Metals Analysis by ICP | ✔ |
✔
|
✔ |
|
Boil Point | ✔ |
✔ |
✔ |
|
SCA Number | ✔ |
✔ |
✔ |
|
Specific Conductance | ✔ |
✔ |
✔ |
|
Visuals | ✔ |
✔ |
✔ |
|
Total Hardness | ✔ |
✔
|
✔
|
|
HPLC | ✔ |
✔ |
||
Nitrite | ✔
|
✔
|
||
Ion Chromotography | ✔ |
✔ |
Innovative, practical, and durable, OIL SAFE lubricant transfer containers are the global standard of choice for industry, having proven themselves as extremely reliable and critical to best practice lubrication programs for well over a decade.
Des-Case products control contamination, while maintaining equipment cleanliness. Des-Case products include state of the art breathers and customized filtration units that work in various applications and operating environments.
R&G Laboratories offers the full line of CheckFluid products that cost effectively reduces sampling time while ensuing a more accurate, reliable sampling process.
We carry a full line of sampling supplies and equipment that make taking samples easier, accurate, and faster.